New-NBDCIMCoolingFeed
Since
v4.7.0.1
SYNOPSIS
Creates a new Cooling Feed in Netbox DCIM module.
SYNTAX
New-NBDCIMCoolingFeed [-Cooling_Source] <UInt64> [[-Rack] <UInt64>] [-Name] <String> [[-Status] <String>]
[[-Cooling_Capacity] <Decimal>] [[-Max_Flow] <Decimal>] [[-Max_Flow_Unit] <String>] [[-Description] <String>]
[[-Tenant] <UInt64>] [[-Owner] <UInt64>] [[-Comments] <String>] [[-Tags] <Object[]>]
[[-Custom_Fields] <Hashtable>] [-Raw] [-ProgressAction <ActionPreference>] [-WhatIf] [-Confirm]
[<CommonParameters>]
DESCRIPTION
Creates a new Cooling Feed in Netbox DCIM module (NetBox 4.7+). A cooling feed delivers cooling capacity from a cooling source to a rack, analogous to a power feed in the power distribution model.
EXAMPLES
EXAMPLE 1
New-NBDCIMCoolingFeed -Cooling_Source 3 -Name 'CF-01' -Rack 12 -Cooling_Capacity 25 -Max_Flow 40 -Max_Flow_Unit lpm
Creates a 25 kW cooling feed from cooling source ID 3 to rack ID 12 with a 40 L/min maximum flow.
PARAMETERS
-Cooling_Source
Cooling source this feed is provisioned from (database ID). Required.
Type: UInt64
Parameter Sets: (All)
Aliases:
Required: True
Position: 1
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Rack
Rack this feed supplies (database ID).
Type: UInt64
Parameter Sets: (All)
Aliases:
Required: False
Position: 2
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Name
Name of the cooling feed. Required.
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: 3
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Status
Operational status: offline, active, planned or failed. Defaults to active server-side.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 4
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Cooling_Capacity
Rated cooling capacity in kW.
Type: Decimal
Parameter Sets: (All)
Aliases:
Required: False
Position: 5
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Max_Flow
Maximum flow rate, expressed in the unit given by -Max_Flow_Unit.
Type: Decimal
Parameter Sets: (All)
Aliases:
Required: False
Position: 6
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Max_Flow_Unit
Unit for -Max_Flow: lpm (liters per minute), m3ph (cubic meters per hour) or gpm (gallons per minute).
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 7
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Description
Brief description.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 8
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Tenant
Tenant assigned to this object (database ID).
Type: UInt64
Parameter Sets: (All)
Aliases:
Required: False
Position: 9
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Owner
Owner of this object (database ID).
Type: UInt64
Parameter Sets: (All)
Aliases:
Required: False
Position: 10
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Comments
Detailed comments (Markdown is supported).
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 11
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Tags
One or more tags to assign to this object (tag names or IDs).
Type: Object[]
Parameter Sets: (All)
Aliases:
Required: False
Position: 12
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Custom_Fields
Hashtable of custom field values to set (cf_\<name>).
Type: Hashtable
Parameter Sets: (All)
Aliases:
Required: False
Position: 13
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Raw
Return the raw API response instead of the results array.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Confirm
Prompts you for confirmation before running the cmdlet.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-ProgressAction
{{ Fill ProgressAction Description }}
Type: ActionPreference
Parameter Sets: (All)
Aliases: proga
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
INPUTS
OUTPUTS
System.Management.Automation.PSObject
NOTES
AddedInVersion: v4.7.0.1 Requires NetBox 4.7.0 or later.