Set-NBDCIMPowerFeed
Since
v4.4.10.0
SYNOPSIS
Updates an existing DCIM PowerFeed in Netbox DCIM module.
SYNTAX
Set-NBDCIMPowerFeed [-Id] <UInt64> [[-Power_Panel] <UInt64>] [[-Name] <String>] [[-Rack] <UInt64>]
[[-Status] <String>] [[-Type] <String>] [[-Supply] <String>] [[-Phase] <String>] [[-Voltage] <UInt16>]
[[-Amperage] <UInt16>] [[-Max_Utilization] <UInt16>] [[-Mark_Connected] <Boolean>] [[-Description] <String>]
[[-Comments] <String>] [[-Tags] <String[]>] [[-Custom_Fields] <Hashtable>] [-Raw]
[-ProgressAction <ActionPreference>] [-WhatIf] [-Confirm] [<CommonParameters>]
DESCRIPTION
Updates an existing DCIM PowerFeed in Netbox DCIM module. Supports pipeline input for Id parameter where applicable.
EXAMPLES
EXAMPLE 1
Set-NBDCIMPowerFeed
Updates an existing DCIM PowerFeed object.
PARAMETERS
-Id
Database ID of the object to update.
Type: UInt64
Parameter Sets: (All)
Aliases:
Required: True
Position: 1
Default value: 0
Accept pipeline input: True (ByPropertyName)
Accept wildcard characters: False
-Power_Panel
Power Panel.
Type: UInt64
Parameter Sets: (All)
Aliases:
Required: False
Position: 2
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Name
Name of the object.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 3
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Rack
Rack assigned to this object (database ID).
Type: UInt64
Parameter Sets: (All)
Aliases:
Required: False
Position: 4
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Status
Operational status.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 5
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Type
Type of the object.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 6
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Supply
Supply.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 7
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Phase
Phase.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 8
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Voltage
Voltage.
Type: UInt16
Parameter Sets: (All)
Aliases:
Required: False
Position: 9
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Amperage
Amperage.
Type: UInt16
Parameter Sets: (All)
Aliases:
Required: False
Position: 10
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Max_Utilization
Maximum permissible draw (percentage)
Type: UInt16
Parameter Sets: (All)
Aliases:
Required: False
Position: 11
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Mark_Connected
Treat the endpoint as connected even without a cable.
Type: Boolean
Parameter Sets: (All)
Aliases:
Required: False
Position: 12
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Description
Brief description.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 13
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Comments
Detailed comments (Markdown is supported).
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 14
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Tags
One or more tags to assign to this object (tag names or IDs).
Type: String[]
Parameter Sets: (All)
Aliases:
Required: False
Position: 15
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Custom_Fields
Hashtable of custom field values to set (cf_\<name>).
Type: Hashtable
Parameter Sets: (All)
Aliases:
Required: False
Position: 16
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Raw
Return the raw API response instead of the results array.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Confirm
Prompts you for confirmation before running the cmdlet.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-ProgressAction
{{ Fill ProgressAction Description }}
Type: ActionPreference
Parameter Sets: (All)
Aliases: proga
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
INPUTS
OUTPUTS
System.Management.Automation.PSObject
NOTES
AddedInVersion: v4.4.10.0