Skip to content

New-NBDCIMCoolingIntakeTemplate

Since

v4.7.0.1

SYNOPSIS

Creates a new DCIM CoolingIntakeTemplate in Netbox DCIM module.

SYNTAX

New-NBDCIMCoolingIntakeTemplate [[-Device_Type] <UInt64>] [[-Module_Type] <UInt64>] [-Name] <String>
 [[-Label] <String>] [[-Type] <String>] [[-Diameter] <Decimal>] [[-Diameter_Unit] <String>]
 [[-Max_Flow] <Decimal>] [[-Max_Flow_Unit] <String>] [[-Description] <String>] [-Raw]
 [-ProgressAction <ActionPreference>] [-WhatIf] [-Confirm] [<CommonParameters>]

DESCRIPTION

Creates a new Cooling Intake Template (NetBox 4.7+). Supports pipeline input for bulk creation.

EXAMPLES

EXAMPLE 1

New-NBDCIMCoolingIntakeTemplate -Device_Type 4 -Name 'Coolant In' -Type 'uqd' -Max_Flow 8 -Max_Flow_Unit 'lpm'

Creates a cooling intake template on device type 4.

PARAMETERS

-Device_Type

Device type this template belongs to (database ID). Mutually exclusive with -Module_Type.

Type: UInt64
Parameter Sets: (All)
Aliases:

Required: False
Position: 1
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-Module_Type

Module type this template belongs to (database ID). Mutually exclusive with -Device_Type.

Type: UInt64
Parameter Sets: (All)
Aliases:

Required: False
Position: 2
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-Name

Name of the template. Use {module} as a placeholder for the module bay position on module type templates.

Type: String
Parameter Sets: (All)
Aliases:

Required: True
Position: 3
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Label

Physical label.

Type: String
Parameter Sets: (All)
Aliases:

Required: False
Position: 4
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Type

Connector type: 'uqd', 'uqdb', 'qdc', 'camlock', 'npt', 'bsp' or 'proprietary'.

Type: String
Parameter Sets: (All)
Aliases:

Required: False
Position: 5
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Diameter

Connector diameter (number, 0.01 - 1000000).

Type: Decimal
Parameter Sets: (All)
Aliases:

Required: False
Position: 6
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-Diameter_Unit

Unit for -Diameter: 'mm', 'cm' or 'in'.

Type: String
Parameter Sets: (All)
Aliases:

Required: False
Position: 7
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Max_Flow

Maximum coolant flow rate (number, 0.01 - 1000000).

Type: Decimal
Parameter Sets: (All)
Aliases:

Required: False
Position: 8
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-Max_Flow_Unit

Unit for -Max_Flow: 'lpm', 'm3ph' or 'gpm'.

Type: String
Parameter Sets: (All)
Aliases:

Required: False
Position: 9
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Description

Brief description.

Type: String
Parameter Sets: (All)
Aliases:

Required: False
Position: 10
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Raw

Return the raw API response instead of the results array.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-WhatIf

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Confirm

Prompts you for confirmation before running the cmdlet.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-ProgressAction

{{ Fill ProgressAction Description }}

Type: ActionPreference
Parameter Sets: (All)
Aliases: proga

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

INPUTS

OUTPUTS

System.Management.Automation.PSObject

NOTES

AddedInVersion: v4.7.0.1

Common parameters

common request params