New-NBDCIMCoolingOutflow
Since
v4.7.0.1
SYNOPSIS
Creates a new DCIM CoolingOutflow in Netbox DCIM module.
SYNTAX
New-NBDCIMCoolingOutflow [-Device] <UInt64> [[-Module] <UInt64>] [-Name] <String> [[-Label] <String>]
[[-Type] <String>] [[-Diameter] <Decimal>] [[-Diameter_Unit] <String>] [[-Cooling_Intake] <UInt64>]
[[-Description] <String>] [[-Owner] <UInt64>] [[-Tags] <Object[]>] [[-Custom_Fields] <Hashtable>] [-Raw]
[-ProgressAction <ActionPreference>] [-WhatIf] [-Confirm] [<CommonParameters>]
DESCRIPTION
Creates a new Cooling Outflow (NetBox 4.7+). Supports pipeline input for bulk creation.
EXAMPLES
EXAMPLE 1
New-NBDCIMCoolingOutflow -Device 12 -Name 'Coolant Out' -Type 'uqd' -Diameter 12.7 -Diameter_Unit 'mm'
Creates a UQD coolant outflow on device 12.
PARAMETERS
-Device
Device this component belongs to (database ID).
Type: UInt64
Parameter Sets: (All)
Aliases:
Required: True
Position: 1
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Module
Installed module this component belongs to (database ID).
Type: UInt64
Parameter Sets: (All)
Aliases:
Required: False
Position: 2
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Name
Name of the component.
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: 3
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Label
Physical label.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 4
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Type
Connector type: 'uqd', 'uqdb', 'qdc', 'camlock', 'npt', 'bsp' or 'proprietary'.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 5
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Diameter
Connector diameter (number, 0.01 - 1000000).
Type: Decimal
Parameter Sets: (All)
Aliases:
Required: False
Position: 6
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Diameter_Unit
Unit for -Diameter: 'mm', 'cm' or 'in'.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 7
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Cooling_Intake
Cooling intake on the same device that this outflow is paired with (database ID).
Type: UInt64
Parameter Sets: (All)
Aliases:
Required: False
Position: 8
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Description
Brief description.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 9
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Owner
Owner for object ownership (database ID).
Type: UInt64
Parameter Sets: (All)
Aliases:
Required: False
Position: 10
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Tags
One or more tags to assign to this object (tag names or IDs).
Type: Object[]
Parameter Sets: (All)
Aliases:
Required: False
Position: 11
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Custom_Fields
Hashtable of custom field values to set.
Type: Hashtable
Parameter Sets: (All)
Aliases:
Required: False
Position: 12
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Raw
Return the raw API response instead of the results array.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Confirm
Prompts you for confirmation before running the cmdlet.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-ProgressAction
{{ Fill ProgressAction Description }}
Type: ActionPreference
Parameter Sets: (All)
Aliases: proga
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
INPUTS
OUTPUTS
System.Management.Automation.PSObject
NOTES
AddedInVersion: v4.7.0.1